thanks. Learn how to install and configure the HPE Smart Array S100i SW RAID driver for your server. Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. Try installing driver hpsa version 6. The HPE OmniStack Firmware update is a comprehensive firmware update solution comprised of two bootable images. HPE Smart Array P440ar Controller . 0 Custom Image, download the ISO from VMware downloads and install. for testing purpose i use 2 HP DL380 Gen 9 servers , i had some problems getting the disks to be recognized as SAS in Windows Server , but after a bit of google time i found out that after deleting all of the RAID config's on the HP P440ar and putting it into HBA Mode , it is possible. Detailed step by step RAID 5 configuration of Smart Array P440ar controller on HP DL380 G9 server, step by step video tutorial available from the live serverArray P440ar, P440, P441, H240nr, P240nr, P542D, and P741m controllers have completed FIPS 140-2 Level 1 validation (certificate #2506). . In fact in theory software should not be able to cause a host BSOD even if the software is buggy. QuickSpecs HPE Smart Array P440ar Controller Standard Features Page 2 Key Features Storage interface (SAS/SATA) • o 8 physical links across 2 x4 internal port s o 12Gb/s SAS, 6Gb/s SATA technology o Mix-and-match SAS and SATA drives to the same controller o Support for SAS tape drives, SAS tape autoloaders and SAS tape libra ries • 2 GiBytes. 15(B) 2023-07-06. 0 build-5310538. then upgrade the firmware to lastest version. Intelligent Provisioning provides installation help for Microsoft Windows, Red Hat and SUSE Linux, and VMware operating systems. Use AHCI SATA mode instead. 00) and renewed the battery. The HPE OmniStack Firmware update is a comprehensive firmware update solution comprised of two bootable images. 04 is not supported. If the running firmware version is previous to GL210xxxx, the Smart Component will block the upgrade with a message. Products. 96W Smart Storage Battery - For DL/ML/SL Generation 9 series of servers - One battery pack provides flash back write cache (FBWC) for all the drive controllers in the server - Connects to the system I/O board, 145mm (5. Patrol readI am having problems installing Debian 7. Universal media bay cabling. Firmware version 6. Before upgrading, read this important information. Mar 30, 2022. P440ar controller LEDs Immediately after you power up the server, the controller runtime LEDs illuminate briefly in a predetermined pattern as part of the POST sequence. 00 Firmware Dependency:. for HPE ProLiant DL, ML and Apollo Servers. Software CD, web, or embedded in the system Software CD or Web Preinstalled in ROM of HP Smart Array controllers When the utility can be used All formats can be run in online and offline environments. HPE Smart Storage Administrator (HPE SSA) for Linux. 24SFF drives at the front and 2SFF drives at the rear of the server — Connect the P440ar controller cables to the 12G SAS Expander port 1 and port 2. Download the latest drivers, firmware, and software for your undefined. The HPE SSA exists in the following interface formats: Although all formats support configuration tasks, some of the advanced tasks are available in only one format. Upgrade to at least 6. We would like to show you a description here but the site won’t allow us. HPE Smart Storage Administrator. New comments cannot be posted and votes cannot be cast. Linux. HP Proliant DL380 G9 / HPE Smart Array P440ar Controller: not detected intermittently. The HP Array Configuration Utility is a web-based application that helps you configure HP ProLiant SMART-2 Array Controllers, HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers. The HPE Smart Storage Administrator (HPE SSA) is a web-based application that helps you configure, manage, diagnose, and monitor HPE ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HPE Storage controllers, and future devices such as SCSI Express drives, and SAS switch. The HPE Smart Array P840ar Controller is a flexible Smart Array 12 Gb/s Serial Attached SCSI (SAS), PCI-Express (PCIe) 3. 0. ESXi showed me a warning on Smart Array P440ar regarding firmware version. Any time the operating system is running During POST, before the operating system is installed Where the utility can be used Any machine that uses aHPE Smart Array P244br Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. Hmmm. This can be done with the following command: # License key installation . 00(D) Last Recommended or Critical Version: 7. 12G SAS Expander Card. 02 or later, the power must be cycled by removing the power cord from the power source, waiting 10 seconds, and then replacing the power cord to activate this important CPLD update. Navigate to the Virtual SAN cluster in the vSphere Web Client. Service Pack for ProLiant. 18. HPE 881457-B21 2. The Smart Storage Admin said rebuilding but then rebuild failed - failed on the P440ar side. The function ends up with "Recover failed due to an unknown error". QuickSpecs HPE Smart Array P440ar Controller Standard Features Page 2 Key Features Storage interface (SAS/SATA) • o 8 physical links across 2 x4 internal port s o 12Gb/s SAS, 6Gb/s SATA technology o Mix-and-match SAS and SATA drives to the same controller o Support for SAS tape drives, SAS tape autoloaders and SAS tape libra ries • 2 GiBytes. 52 is included in the Service Pack for ProLiant (SPP) Version 2016. 00 - cp039995. 1. . • English, French, German, Italian, Japanese, Simplified Chinese, and Spanish languages are supported. Description. . 1038-1 and Firmware version affected: 1. Smart Path requires updated firmware, drivers, and configuration utility available at: HPE SSD Smart Path is ideal for read intensive. Learn more at the Official Hewlett Packard Enterprise Website. Servers. Specification. Download Software. /ssacli ctrl slot=5 lk. Hi there, few days ago i installed my test system with esxi 6. Communities. It features eight internal physical links and delivers increased server. The National Institute of Standards and Technology (NIST) issued the FIPS 140–2 requirements and standards for cryptography modules that include both hardware and software components. 5 RHEL. 872481-B21. This will help ensure the destination controller can properly understand all metadata written to the headers on the source controller. 60 releases with things like this. Whether you're a large enterprise or a smaller business, Hewlett Packard Enterprise data protection and recovery software will cost-effectively protect you against disaster and ensure business continuity. of 14. Deploys and manages HPE Secure Encryption, a data protection solution. 1. 0, are ideal for maximizing performance while supporting advanced RAID levels with up to 4 GB flash-backed write cache (FBWC). 74-1OEM. 0. 5. • On-Line Spares: There is no limit to the number of spare drives that can be installed prior toIts fault recovery protects from image corruption firmware by making a redundant copy and saving the firmware image. Re: Smart Array P440ar in Embedded Slot - The cache is permanently disabled Hi, Yes I have already tried to re-enabled the cache settings but problem remain so let me replace the controller card since cache memory is embedded and confirm you the final status soon. proprietary software components. Took a drive from the P440ar controller side, I swapped it with the bad disk from P840. 0 U2 Running 2 VM's 1 Gaming Server (Used as an temporary Gaming-Machine with the RTX, works well for its configuration). may have older product names and model numbers that differ from current models. Select "get drivers, software, and firmware. AlphaVPS - Alex. 04), upgrading iLO 4 to 2. . ) But with a Cache we get much better results. 0. Wed Apr 08 2020 00:00:00 GMT-0700 (Pacific Daylight Time) a00117194: 2023. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. To locate the drivers for a server, go to the Hewlett Packard Enterprise Support Center website, and then search for the product name/number. The proper way of doing it is to reboot your server and hit F10 key during POST, which will bring you to "Intelligent provisioning" option where you have firmware update tool. このガイドでは、HP Smartアレイコントローラーの機能、取り付け、および設定に関する情報について説明します。Troubleshooting Update. Learn about our open source products, services, and company. This issue occurs when there are multiple SmartCache logical drives configured on a single SmartCache Array (512e SSD). - p440ar make the fans sound like a rocket. 2. thanks, Kev If you are looking for the latest software for your HPE Smart Array P440 Controller, you can download it from this webpage. The webpage provides the latest firmware update for the HPE Smart Array P420 Controller, a high-performance SAS RAID controller for HPE ProLiant servers. The p440ar's had an issue where I had to physically unseat them after a power drain, boot the system once without, and then shutdown and power drain again before reinstalling the controller once more. vib for P440ar? Solved: When I goto:. 0. HPE ProLiant DL388 Gen9 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. If the active firmware image becomes corrupt, the controller will use the redundant firmware image and continue operating. HPE Smart Array P420 Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. 64 (cp037982. If a failure occurs, recovery begins with an On-Line Spare and data is reconstructed automatically. Select your software and. 05 Service Pack for Proliant G9/G10. 5. The update fixes several issues and improves the stability and performance of the controller. 00-1. It features eight internal physical links and delivers increased server uptime by. Functionally, the other. el 20-12-2019 09:40 AM. I have HP 10Krpm SAS deives and intel D3-S4510 series SSDs. HPE Smart Storage Administrator: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. M. このガイドでは、HP Smartアレイコントローラーの機能、取り付け、および設定に関する情報について説明します。 Troubleshooting Update. They all behave similarly. 52-6. 128 (and as per above these appear to be a non-matching pair). 15(B) 2023-07-06. Upgrade to at least 6. HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers. 00 : HPE NS204i OS Boot Device - Critical Firmware Update Required to Prevent Potential Data Inconsistency Issues During Volume Rebuild HP ProLiantサーバー用HP Smart アレイコントローラー. The HPE Smart Array P440ar Controller is a Flexible Smart Array, 12Gb/s SAS RAID controller that provides enterprise-class storage performance, increased internal scalability with SAS Expander Card, and. 56, a few days ago. 00 Previous Version of Firmware: 6. Hmmm. Welcome to Software and Drivers for . The installation is complete. In our testing, applying the recommended firmware on servers with this configuration will cause the server to freeze at post. As mentioned earlier, with modern firmware, you can use any disks you want. 88. Reboot the host & perform a scan and walah. Firmware/Drivers and Software for Intel® RAID and Storage Products. It looks like a sinus wave. 3 The HP Dynamic Smart Array B110i/B120i/B320i controller for Ubuntu 14. 02 includes an update to the embedded controller’s CPLD image. Version History: RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. Before SATA, hotplug was one of the reasons people bought hardware RAID -- one of the common failure modes for software RAID was disks failing during the power cycle and reboot from a degraded RAID that you needed to swap an IDE drive, and that's where the reputation of software RAID as unreliable comes from. 03 (or earlier) is updated to v2. • English, French, German, Italian, Japanese, Simplified Chinese, and Spanish languages are supported. Smart Array P440ar in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: PDNLH0BRH753PJ Cache Serial Number: PDNLH0BRH753PJ RAID 6 Status: Enabled Controller Status: OK Hardware Revision: B Firmware Version: 7. Advisory and Transformation Services. HPE Technology Service Portfolio. Urgend - DL380G9 / ILO says: Failure of HP Smart Array P440ar Firmware 3. Unfortunately we couldn't get the server to boot. A new version of firmware can be flashed to the ROM while the c ontroller maintains the last known working version of firmware. The document also includes installation instructions, configuration. 00 Previous Version of Firmware: 6. LG Spirit LTEH440V. You are viewing the most relevant and current results for this product. + HP 881457-B21 Enterprise - Hard drive - 2. ~ # esxcli hpssacli cmd -q “controller slot=0 modify hbamode=on forced". Get it Nov 3 - 8. Logical drive initialization. Service Pack for ProLiant. HPE Technology Service Portfolio. Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. The minimum supported OS for the HP Flexfabric 10Gb 2-port 526 FLR-SFP+ adapter is 12. Product Bulletin, research Hewlett Packard Enterprise servers, storage, networking, enterprise solutions and software. 550. 0; using interactive mode, deselect the firmware version 4. This firmware update is provided as a bootable, off-line tool that will install new firmware onto the server. Lastly, since these are different models, you want to make sure the release date on the Gen9's P440ar Firmware is newer than the P420, by DATE of release). This solution uses HP Smart Update Manager (HP SUM) as the deployment tool. 0 x8 RAID controller that provides enterprise-class storage performance, increased internal scalability, and data protection for HPE ProLiant DL360 and DL380 Gen9 rack servers. . Product Bulletin, research Hewlett Packard. When the update tool is run it will indicate firmware versions currently installed on the server. HPE Smart Array P420 Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. HPE Technology Service Portfolio. This issue occurs when there are multiple SmartCache logical drives configured on a single SmartCache Array (512e SSD). It normally runs a KVM instance directly, but I don't have it set up to autoboot to save time while testing. . Open chassis, ESD ground yourself on the side of the chassis, remove the SAS cabling from the P440ar, and then remove the p440ar, and unplug the battery from the board. 4. Firmware Upgrades of DL 380 Gen9 . 65(B) (also denoted as 1. The following process was used: Shut down server. There is any software to mesure the IOs? Thanks. Select Update Firmware. Product Bulletin, research Hewlett Packard. 52, Hardware Revision: B. Just trying to keep some terminology straight here. The next piece of firmware to execute might actually be the firmware of the Smart Array P440ar Controller. 11 unfortunately. -Check current firmware-Locate newest firmware from vendor-Upload firmware-Reboot Open-E DSS V7Storage software that gets the job done: · Data Protection and Recovery Software. 4. With 4 times the better SSD read performance in the HP smart array P440ar RAID controller, the HPE Solid-state drive Smart Path chooses the right path to the SSD and then it accelerates the reads for all the RAID levels. Have the same problem with HP DL360 Gen9 server and Smart Array P440ar controller in HBA mode. 5. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. 56 (or later). This document provides the user guide for the HP Array Configuration Utility (ACU) CLI, a tool that allows users to configure and manage HP Smart Array controllers and logical drives. If the firmware becomes corrupt, the controller will revert back to the previous version of firmware and continue operating. 06 is not supported for vSAN on P440 nor P440ar, nor is driver 6. This release of Gen9 Service Pack for ProLiant (SPP) including support for Gen9 Blade systems is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers. Hewlett Packard Enterprise support portal for business, enterprise and IT users. Software and Firmware versioning info from CIM Providers. 00How to swicth HP proliant Gen8 P420i smart array controller to hda - mode. 5" disks aren't that large in capacity, so you wouldn't be running into issue with that anyway. 02_B0, I find it stange it has no issue with the 16TB EXOS drives which are also quite new, so I don't think that's the issue. It has P440ar adapter, which works with the "new" hpsa driver. Find the latest firmware, drivers, software and utilities downloads for current generation Intel® RAID/Storage products below. The HPE SSA is a configuration and management tool for HPE Smart HBA and Smart Array controller options. Option 2 sounded much better. Showing 1-10 of 529. This is HP’s official website to download the correct drivers free of cost for Windows and Mac. Part Description. 52, and 5. may have older product names and model numbers that differ from current models. Here is the config: Text => ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: P61620F9VV6I1I Cache Serial Number: PA2270H9VV538J RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware. Procedure Download the. Proactive notifications; Service Pack for ProLiant. Feb 15, 2018. Collapse all. 4TB 10000RPM 2. Read developer tutorials and download Red. ESXi showed me a warning on Smart Array P440ar about the firmware version: 3. If you need to update the ROM images of your HPE Intel Ethernet NICs running under Linux x86_64 platform, you can download this package and use the utilities and binaries provided. Created attachment 276123 shutdown log [`dmesg -n debug` added, otherwise normal systemd-obfuscated user messages] This particular test machine is a MAAS server, 4 interfaces, 2 bonds, 2 bridges. Standard on the P440ar are RAID 6, RAID 60, RAID 1 ADM, Capacity Expansion, mirror split, recombine, and rollback in Online Mode, Drive Erase, Performance Optimization-Degraded Reads and Read Coalescing, Move/Delete any individual LUNS The HP SSD Smart Path feature included in the Smart Array software stack improves SSDFirmware can only be upgraded from the last two major firmware releases. 52. Controller firmware was 2. Software Details - System ROM Flash Binary - HPE ProLiant DL160 Gen9/DL180 Gen9 (U20) Servers | HPE Support. 52. HP DL360 with a HP SmartArray P440ar in HBA mode with four HP SSDs. Firmware | SATA Storage Disk. Reboot the host & perform a scan and walah. 65-0 in the VMware Compatibility Guide): Printer Setup, Software & Drivers; Printing Errors or Lights & Stuck Print Jobs; DesignJet, Large Format Printers & Digital Press; Sprocket; Samsung; Printers Knowledge Base; Printer Wireless, Networking & Internet; Printer Ink Cartridges & Print Quality; Printer Paper Jams & Feed Issues; Desktops Desktop Software and How To Questions Re: How do I download firmware . Software, firmware, and utilities. Product: Smart Array P440ar. Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. 0. This can be done with the following command: # License key installation . Yes it is a custom HPE/PMC Sierra design, > microsemi > MicroChip. HPE Smart Array P440 Controller. 15(B) 2023-07-06. Flashing blue The drive carrier firmware is being updated or requires an update. 00(B) Previous Version of Firmware: 7. 04. The easiest way to do this on HP servers is to download HP Service Pack for Proliant. get on the vSAN HCL for vSAN version X and then losing interest, not bothering about later vSAN versions. Search the support knowledge base, download drivers and patches, create and manage cases, and learn from expert users in forums. The Service Pack for ProLiant (SPP) is a systems software and firmware solution delivered as a bootable ISO. Firmware | SATA Storage Disk. 2 SSD Enablement Board option cabling. The solution uses Smart Update Manager (SUM) as the deployment tool and is tested on all HPE ProLiant Gen9 servers as defined. 52. Otherwise, continue with step 4. Victor 0 08-08-2016, 08:24 AM #2. May 13, 2021. 10. HPE ProLiant DL/ML/BL Server - How to Upgrade/Downgrade Controller Firmware from BIOS. Servers for Internet of Things. And every 8 hdd's connected is green/ok. This document is subject to change without notice. For this reason, when first upgrading firmware on an embedded controller from an older version to version 4. more or less unattended while you enjoy a cup of coffee or do some other work. Release Date. Actual. TechNet; Products; IT Resources; Downloads; Training; Support. LG Spirit LTEH442F. 88?) what does 0 mean? I searching the whole HPE download center and did not found it. . P440ar controller LEDs Immediately after you power up the server, the controller runtime LEDs illuminate briefly in a predetermined pattern as part of the POST sequence. Search the support knowledge base, download drivers and patches, create and manage cases, and learn from expert users in forums. Detailed step by step RAID 5 configuration of Smart Array P440ar controller on HP DL380 G9 server, step by step. The HPE Smart Storage Administrator (HPE SSA) is a web-based application that helps you configure, manage, diagnose, and monitor HPE ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs),. Any idea what's wrong? I guess HPE will call me in a day or two (like. Tech Courier. The HPE Smart Array P440 Controller is a 12Gb/s SAS RAID controller that offers high performance, scalability and data protection for HPE ProLiant Gen9 servers and Apollo systems. Remove power from server, hold power button for 15 seconds. If the running firmware version is previous to GL210xxxx, the Smart Component will block the upgrade with a message. Release Device Driver Firmware Package Version Firmware Version Queue Depth Driver Type vSAN Type Features And points out a problem with HP's software. Learn more at the Official Hewlett Packard Enterprise Website. Select Browse. Use the HP Smart Storage Utilities for Linux to modify the RAID configuration within the host OS. However, the cabling for the P440ar controller remains the same. rpm 7. 5. Second option is to download and run HP SUM (Smart Update Manager) on any other computer/server on the same network and as a target add your core server. O/S VMWare 5. Then tried to recover the cache module via Smart Storage Administrator. 7-inch) long cable. 3. Server mode; Smart Update ManagerChose Embedded RAID 1: Smart Array P440ar controller. You will also find the release notes. Doing these steps did get the server back online. 52. 1331820 driver. All are HP Proliant DL360 gen9 with Smart Array P440ar Raid Controller, Xeon E5-2620v4, 32GB RAM. If the firmware becomes corrupt, the controller will revert back to the previous version of firmware and continue operating. 52 or newer. x86_64. " Locate, download, and install Smart Array Firmware Version 3. Support. RoHS. 5. Overview 6 Using HP SSA over other configuration utilities provides the following benefits: • GUI, CLI, and Scripting interfaces are available. Proactive notifications; Service Pack for ProLiant. The other bootable side rebuild went perfect. Showing. 5. smj. All firmwares were updated to their most recent versions, so I believe that utility was also most recent version. Memory Size: 2GB. Operating System: Linux. 74-1OEM. I. Went into the HP array management software, decided I would delete the logical drive and rebuild it -- maybe windows server would see it now. disks will show up in vSphere web client for vSAN. The installation is complete. Online HDD/SSD Flash Component for Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives. 15(B) 2023-07-06. P840 on the bootable, P440ar on the other 2. Off = Deactivated *When all four LEDs described in this table flash simultaneously, a power fault has occurred. Showing 2 of 2. BenefitsUpdate the server firmware ("Methods for updating the firmware" on page 12). The LSI HBA isn't something radical. The iLO firmware version has already been displayed, so the firmware module related to the initialization of the iLO functionality is probably already successfully executed. Thanks for your help!IT Configuration is the following : - Server ProLiant ML350 Gen9 E5-2620v3 2. This release of Gen9 Service Pack for ProLiant (SPP) including support for Gen9 Blade systems is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. Controller: Smart Array P440ar in Embedded Slot Device: Logical Drive 2 Severity: Warning Message: This logical drive has Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Support. HPE 1. Proactive notifications. HP Smart Array P440ar controller: Device Type : SAS: DID : 3239: Brand Name : HP: SVID : 103c: Number of Ports: 8: SSID : 21c0: VID : 103c: Notes: Firmware versions listed are. Re: How do I download firmware . HPE P440ar/P840ar Flexible Smart Array Controller. This reduces the risk of flashing firmware to the controller. 5 or VMware ESXi 6. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. HPE Smart Array P440 Controller: Access. ago. more platform independent when using software RAID / device mapper devices. After conducting a very thorough investigation, HPE and the vendor are confident that they have identified the root cause of the issues and on August 11, 2020, HPE released HPE. HPE 1. 4. I have installed ESXi 6. Explore the new digital customer experience engagement platform. 88 Firmware Dependency: None. 0 Version: 4. Compare the features and benefits of the P440 with other HPE Smart Array controllers and related options. 56, a few days ago. 550. 2. 0 U3 (latest in compatibility list) - we did not reach this point yet. Download the latest firmware update for Windows (x64) and learn how to install it from this webpage. 7. For Information, i use 4 of this SAS: Seagate, ST1200MM0088. RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. The HP Array Configuration Utility is a web-based application that helps you configure HP ProLiant SMART-2 Array Controllers, HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers. Controller firmware was 2. So all those customers get these warnings after a major upgrade (6. Intelligent Provisioning prepares the system for installing "off-the-shelf" and Hewlett Packard Enterprise branded versions of operating system software and integrates optimized ProLiant server support software. May 13, 2021. Showing 2 of 2.